ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM
ELECTRICAL PANEL CLEAN AGENT SYSTEM

ELECTRICAL PANEL CLEAN AGENT SYSTEM

Price 75000.0 INR/ Unit

MOQ : 1 Unit

ELECTRICAL PANEL CLEAN AGENT SYSTEM Specification

  • Feature
  • Automatic Operation, Non-Conductive, Residue-Free, Safe for Sensitive Equipment
  • Power
  • No electrical power required for operation
  • Type
  • Electrical Panel Clean Agent System
  • Raw Material
  • Mild Steel Cylinder with Clean Agent Gas
  • Size
  • Customizable as per requirements
  • Water Content
  • 0% (Dry Agent)
  • Installation Method
  • Direct Inside or Above Electrical Panels
  • Discharge Time
  • 10 seconds average
  • Approval/Certification
  • UL Listed, FM Approved (varies by model/manufacturer)
  • Application
  • Electrical Panels, Server Rooms, Control Panels, Data Centers
  • Operating Pressure
  • 25 Bar (360 psi) at 21C
  • Cylinder Capacity
  • Based on design, commonly 5 to 100 Kg
  • Nozzle Type
  • Diffusion/Discharge nozzle for even agent dispersion
  • Environmentally Safe
  • Yes, does not deplete ozone layer (ODP=0)
  • Activation Method
  • Automatic and Manual Release
  • Extinguishing Agent
  • FM 200 / HFC-227ea / Clean Agent Gas
 
 

ELECTRICAL PANEL CLEAN AGENT SYSTEM About

Electrical panel clean agent systems are designed to provide fire suppression for electrical panels, ensuring safety in high-risk environments. These systems typically use clean agents like HFC-227ea and FK-5-1-12, which are safe for electronics, leave no residue, and require no cleanup.
Key features include:

Comprehensive Protection for Critical Electronic Spaces

Engineered for environments where electrical continuity is paramount, this clean agent system defends electrical panels and technology assets against fire. It deploys both automatically and manually, delivering rapid suppression without water or residue, preventing damage and downtime in server rooms, control centers, and similar sensitive locations.


Efficient and Safe Clean Agent Technology

Utilizing extinguishing agents like FM 200 or HFC-227ea, the system offers quick fire knockdown, low operating pressure, and a completely dry, non-conductive formula. Certified by international standards and fabricated from robust mild steel, it ensures superior safety, installation flexibility, and minimal environmental impact with zero ozone depletion potential.

FAQ's of ELECTRICAL PANEL CLEAN AGENT SYSTEM:


Q: How does the Electrical Panel Clean Agent System operate during a fire emergency?

A: This system can be activated automatically through built-in detectors or manually using release stations. Once activation is triggered, the clean agent is rapidly discharged through diffusion nozzles, saturating the panel area within about 10 seconds to suppress the fire effectively and safely.

Q: What types of environments are most suitable for installing this fire suppression system?

A: It is designed for use in spaces with high-value or sensitive electronic equipment, such as electrical panels, server rooms, data centers, control panels, and telecom facilities. Its installation can be tailored for direct placement inside or above electrical panels.

Q: What are the main benefits of using a clean agent fire suppression system over traditional sprinklers?

A: Clean agent systems are non-conductive, residue-free, and do not introduce water or moisture, making them ideal for sensitive electronics. They quickly extinguish fire without causing equipment damage or post-discharge mess, thus reducing downtime and cleanup costs.

Q: When should this system typically be serviced or inspected?

A: Regular maintenance is recommended at least annually, or as per local regulatory safety standards. Periodic inspection ensures system readiness, verifies pressure and agent levels, and confirms that detection mechanisms are functioning correctly.

Q: Where are the cylinders and nozzles installed for optimal performance?

A: Cylinders are strategically placed based on room size and risk assessment, commonly near or within the electrical panels, while nozzles are positioned to ensure even agent distribution. Exact placement is determined during professional system design to maximize protection.

Q: What makes FM 200 and HFC-227ea safe for both people and the environment?

A: Both FM 200 and HFC-227ea are non-toxic at design concentrations, leave no residue, are electrically non-conductive, and have zero ozone depletion potential (ODP=0), making them safe for occupied areas and environmentally responsible.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Clean Agent System Category

FM 200 Fire Suppression system

FM 200 Fire Suppression system

Price 70000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Type : Other, FM 200 Fire Suppression System

Feature : Automatic detection and actuation, electrical integration, rapid discharge, nonresidual clean agent, safe for electronics

Raw Material : FM200 (Heptafluoropropane) gas with highpressure steel or aluminum cylinder

Power : Typically less than 50W for control panel

SERVER ROOM SUPRESSION SYSTEM

SERVER ROOM SUPRESSION SYSTEM

Price 105000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Type : Other, Automatic Clean Agent Fire Suppression System

Feature : No residue, nonconductive, rapid action, suitable for sensitive equipment

Raw Material : Steel Cylinder; Clean Agent Gas (FM200, NOVEC 1230, or CO2)

Power : 1030W (control panel and detection circuits)

ILP Clean Agent system

ILP Clean Agent system

Price 75000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Type : Other, Clean Agent Fire Suppression System

Feature : Automatic fire detection and suppression, local alarm

Raw Material : Mild Steel (Cylinder), Electrical Components (Control Unit)

Power : Less than 10 Watts (for detection and actuation)

DLP Clean Agent system

DLP Clean Agent system

Price 30000.0 INR / Gallon

Minimum Order Quantity : 1 Gallon

Type : Other, Automatic Clean Agent Fire Suppression System

Feature : Automatic Fire Detection & Suppression, WallMount, Compact Design

Raw Material : Mild Steel (Enclosure), Electrical Components, Clean Agent Cylinder

Power : 3050W (Typical for Panel & Detection)



" We mainly want inquiries from Gujarat, Rajasthan, Madhya Pradesh, Maharashtra, Goa. "