Call UsCall Us 07971670816
Fume Hood Fire Suppression System
Fume Hood Fire Suppression System

Fume Hood Fire Suppression System

Price 56000 INR/ Set

MOQ : 25 Sets

Fume Hood Fire Suppression System Specification

  • Voltage
  • 24V DC (For Alarm and Control Panel)
  • Fire Extinguisher Type
  • Clean Agent or ABC Dry Chemical
  • Coating Type
  • Epoxy Powder Coating
  • Mounting Type
  • Wall/Cabinet/Fume Hood Mounted
  • Shape
  • Cylindrical (Cylinder) and Linear (Pipe)
  • Working Temperature
  • 0C to 55C
  • Operating Pressure
  • 1012 bar
  • Installation Type
  • Ducted/Unducted Fume Hood, Overhead Mount
  • Technology
  • Automatic Detection and Suppression
  • Features
  • Direct Action, Fast Response, Clean Agent, Non-residue
  • Fire Class
  • Class A, B, and C Fires
  • Connectivity Type
  • Hardwired with Optional Alarm Integration
  • Coverage Area
  • Up to 23 meter hood width per nozzle
  • Control Type
  • Automatic with Manual Override
  • Application
  • Fume Hood Fire Suppression
  • Max Flow Rate
  • 30 LPM (Standard for system nozzles)
  • Capacity
  • 2 Kg 10 Kg (Based on Hood Size)
  • Diameter
  • 16 mm Pipe (Typical)
  • Pressure
  • 12 bar (Cylinder Charging)
  • Discharge Time
  • Less Than 30 Seconds
  • Nozzle Type
  • Mist or Flooding
  • Cylinder Material
  • Seamless Steel or SS304
  • Agent Type
  • HFC-227ea or ABC Powder
  • Resetting Requirement
  • Manual Re-charge after Activation
  • Activation Time
  • <10 Seconds Upon Fire Detection
  • Compliance Standard
  • NFPA/IS
  • Alert Mechanism
  • Audio-Visual Alarm Output
  • Detection Method
  • Heat Sensing Tube
 

Fume Hood Fire Suppression System Trade Information

  • Minimum Order Quantity
  • 25 Sets
  • Payment Terms
  • Cheque
  • Main Export Market(s)
  • Asia
  • Main Domestic Market
  • All India
 

Fume Hood Fire Suppression System About



Discover the trending ASHA Fume Hood Fire Suppression System, a masterful solution engineered for advanced laboratory safety. This premier system is fabricated from seamless steel or SS304 and features a heat sensing tube for immediate detection, activating in under 10 seconds. With robust, soaring coverage for Class A, B, and C fires, its clean agent technology leaves no residue and swiftly discharges in less than 30 seconds. Grab yours now during our exclusive promotion, and experience one of the finest automatic protection solutions available for industrial settings in India.

Exceptional Versatility for Crucial Environments

The Fume Hood Fire Suppression System is meticulously suitable for use in industrial and laboratory setups, safeguarding against multiple fire classes and hazardous scenarios. It is specifically designed for fume hood fire suppression but can be utilized in a wider general industrial context as well. Used as an automatic safety measure, it provides reliable protection where potentially volatile reactions are performed, ensuring a safe workspace for critical applications.


Express Delivery and Seamless Supply Management

Our Sample Policy ensures every customer can evaluate the Fume Hood Fire Suppression System before large-scale implementation. Enjoy express shipping with timely deliveries for all bulk and single-unit orders. With a robust supply ability, shipments are dispatched swiftly to meet urgent requirements, and payment terms are flexible for ease of procurement. Each system is delivered ready to install, ensuring quick and hassle-free integration across India.


Type Cylinder
Brand ASHA
Capacity AS PER SITE
Packaging Type SET
Usage/Application Industrial
Material Mild Steel
Fire Extinguisher Type ANY
Environment Temp ANY
Fire Suppression Type Pipeline, Fire Extinguisher, Cylinder


FAQ's of Fume Hood Fire Suppression System:


Q: How does the Fume Hood Fire Suppression System detect and suppress fires?

A: It utilizes a heat sensing tube for masterful automatic fire detection, activating within 10 seconds and discharging the agent in under 30 seconds to suppress Class A, B, and C fires effectively.

Q: What is the process after the system is activated for fire suppression?

A: Once activated, the system must be manually recharged. The seamless cylinder needs refilling by certified professionals to restore full operational readiness, ensuring ongoing safety.

Q: Where can the system be installed, and what types of hoods is it suitable for?

A: The system is designed for both ducted and unducted fume hoods, supporting overhead, wall, cabinet, or direct hood mounting. It is ideal for laboratories, industrial settings, and any space with fume hood requirements.

Q: What are the benefits of using a Clean Agent like HFC-227ea in the system?

A: A Clean Agent leaves no residue, ensuring protection of sensitive equipment and work surfaces while delivering rapid fire suppression without secondary damage.

Q: When can I expect shipment and installation assistance for my order?

A: Express shipping is available, and all systems are delivered promptly. Installation support or integration guidance is provided to ensure swift deployment post-delivery.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



" We mainly want inquiries from Gujarat, Rajasthan, Madhya Pradesh, Maharashtra, Goa. "
Back to top