SERVER ROOM SUPRESSION SYSTEM
SERVER ROOM SUPRESSION SYSTEM
SERVER ROOM SUPRESSION SYSTEM
SERVER ROOM SUPRESSION SYSTEM
SERVER ROOM SUPRESSION SYSTEM
SERVER ROOM SUPRESSION SYSTEM
SERVER ROOM SUPRESSION SYSTEM
SERVER ROOM SUPRESSION SYSTEM
SERVER ROOM SUPRESSION SYSTEM
SERVER ROOM SUPRESSION SYSTEM
SERVER ROOM SUPRESSION SYSTEM
SERVER ROOM SUPRESSION SYSTEM

SERVER ROOM SUPRESSION SYSTEM

Price 105000.0 INR/ Piece

MOQ : 1 Piece

SERVER ROOM SUPRESSION SYSTEM Specification

  • Light Source
  • LED visual indication on control panel
  • Power
  • 10-30W (control panel and detection circuits)
  • Feature
  • No residue, non-conductive, rapid action, suitable for sensitive equipment
  • Voltage
  • 24V DC (for detection and actuation systems)
  • Type
  • Automatic Clean Agent Fire Suppression System
  • Raw Material
  • Steel Cylinder; Clean Agent Gas (FM-200, NOVEC 1230, or CO2)
  • Size
  • Varies by server room capacity, typically 10-80L cylinder volume
  • Length
  • 1200 mm (typical cylinder height)
  • Width
  • 250 mm (cylinder diameter)
  • Thickness
  • 5-8 mm (cylinder wall thickness)
  • Density
  • Gram per cubic centimeter(g/cm3)
  • Thermal Conductivity
  • Non-applicable (not used for insulation)
  • Water Absorption
  • Non-applicable (uses gas-based or clean agent suppression)
  • Water Content
  • Not applicable (gas-based system)
  • Refill Availability
  • Yes, easy cylinder refilling and replacement
  • Temperature Range
  • 0C to +54C (operational)
  • Coverage Area
  • Up to 200 m2 per system (expandable)
  • Compliance Standard
  • UL, FM, EN 12094, NFPA 2001
  • System Lifespan
  • 10-15 years with proper maintenance
  • Cylinder Finish
  • Red Epoxy Powder Coated
  • Activation Method
  • Automatic and Manual Actuation
  • Audio Alarm Output
  • 90 dB @ 1m (typical)
  • Suppression Agent Options
  • FM-200, NOVEC 1230, CO2
  • Detection Method
  • Smoke and Heat Detectors
  • Operating Pressure
  • 24-42 bar (varies by agent)
  • Control Panel
  • Microprocessor-based with fault and alarm indicators
  • Discharge Time
  • Typically less than 10 seconds
  • Pipe Material
  • Corrosion-resistant Stainless Steel or Galvanized Iron
  • Maintenance Requirements
  • Annual inspection; Bi-annual refilling check
 
 

SERVER ROOM SUPRESSION SYSTEM About

The best fire suppression systems for server rooms are clean agent systems such as FM200, Novec 1230, or inert gas systems, because they extinguish fires quickly without damaging sensitive electronic equipment .


  • FM200 (HFC227ea) Fast discharge, effective on Class C electrical fires.
  • Novec 1230 Low global warming potential, residuefree, safe for electronics.
  • Inert Gas Systems (Inergen, Argonite) Reduce oxygen to suppress fire without harming

  • NFPA 75 Fire protection for IT equipment; recommends clean agents or preaction sprinklers.
  • NFPA 76 Telecom facility fire protection.
  • NFPA 2001 Clean agent system design and safety requirements.
  • IBC Often requires automatic sprinkler systems in commercial buildings.
  • EPA SNAP Restricts highGWP agents and promotes environmentally friendly alternatives

  • Protect equipment without causing collateral damage.
  • Integrate suppression with HVAC shutdown and power isolation.
  • Ensure sealed room integrity for gasbased systems.
  • Regular testing and maintenance per NFPA guidelines


Rapid, Residue-Free Protection for Critical Infrastructure

Our server room suppression systems are engineered to safeguard mission-critical environments without leaving residue or damaging equipment. Utilizing advanced agents like FM-200, NOVEC 1230, or CO2, the system activates automatically or manually, suppressing fires in under 10 seconds. With corrosion-resistant stainless steel or galvanized iron pipes and a microprocessor-based control panel, it provides robust and reliable protection up to 200 m2 per system. Easy refilling and maintenance ensure system longevity and readiness at all times.


Advanced Detection and Actuation Designed for Server Rooms

Equipped with smoke and heat detectors, the system ensures early fire identification and swift activation. Users benefit from both automatic and manual actuation options, giving unparalleled flexibility and control. The control panel features clear LED visual status and high-decibel audio alarms, increasing safety and clarity in an emergency. Annual inspections and straightforward refilling procedures keep the system in peak condition and fully compliant with leading fire safety standards.

FAQ's of SERVER ROOM SUPRESSION SYSTEM:


Q: How is the server room suppression system activated during a fire emergency?

A: The system can be activated automatically through smoke and heat detectors or manually using dedicated actuation switches. Upon detection, the suppression agent is released within seconds to quickly extinguish the fire and protect vital equipment.

Q: What suppression agents are available and what are their advantages?

A: The available agents are FM-200, NOVEC 1230, and CO2. These clean agents offer rapid fire suppression without leaving any residue, are non-conductive, and are specifically chosen for their suitability in environments with sensitive electronics.

Q: When does the suppression agent discharge and how long does it take?

A: Once the control panel receives a signal from the detectors or manual activation, the suppression agent discharges typically in less than 10 seconds, ensuring swift fire control and equipment protection.

Q: Where can this suppression system be installed and what coverage does it provide?

A: The system is ideal for server rooms and critical IT spaces, covering up to 200 m2 per system. Multiple systems can be connected to protect larger areas, offering flexible installation options for distributors, service providers, and end-users.

Q: What is the maintenance process for the suppression system?

A: Annual inspections and bi-annual refilling checks are recommended. Refilling and cylinder replacement are designed for ease, ensuring continued operation and compliance with relevant safety standards.

Q: How does the system ensure clear notification and situational awareness during an emergency?

A: The control panel delivers visual alerts through LEDs and audio alarms at around 90 dB at 1 meter, providing clear and timely notification to personnel for swift evacuation and response.

Q: What are the main benefits of choosing this server room suppression system?

A: Key benefits include rapid, residue-free suppression, non-damaging protection for sensitive electronics, robust corrosion-resistant construction, and compliance with international safety standards. Easy maintenance and refill procedures further support operational reliability and safety.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Clean Agent System Category

FM 200 Fire Suppression system

FM 200 Fire Suppression system

Price 70000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Feature : Automatic detection and actuation, electrical integration, rapid discharge, nonresidual clean agent, safe for electronics

Size : Modular, suitable for panel protection or small areas

Type : Other, FM 200 Fire Suppression System

Raw Material : FM200 (Heptafluoropropane) gas with highpressure steel or aluminum cylinder

ILP Clean Agent system

ILP Clean Agent system

Price 75000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Feature : Automatic fire detection and suppression, local alarm

Size : Standard Cylinder (Capacity customizable)

Type : Other, Clean Agent Fire Suppression System

Raw Material : Mild Steel (Cylinder), Electrical Components (Control Unit)

DLP Clean Agent system

DLP Clean Agent system

Price 30000.0 INR / Gallon

Minimum Order Quantity : 1 Gallon

Feature : Automatic Fire Detection & Suppression, WallMount, Compact Design

Size : Customizable Dimensions

Type : Other, Automatic Clean Agent Fire Suppression System

Raw Material : Mild Steel (Enclosure), Electrical Components, Clean Agent Cylinder

Clean Agent Suppression System

Clean Agent Suppression System

Price 30000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Feature : Automatic Fire Suppression, NonConductive, Leaves No Residue

Size : 4 kg (typical size, varies by model)

Type : Other, Clean Agent Fire Suppression System