No residue, non-conductive, rapid action, suitable for sensitive equipment
Voltage
24V DC (for detection and actuation systems)
Type
Automatic Clean Agent Fire Suppression System
Raw Material
Steel Cylinder; Clean Agent Gas (FM-200, NOVEC 1230, or CO2)
Size
Varies by server room capacity, typically 10-80L cylinder volume
Length
1200 mm (typical cylinder height)
Width
250 mm (cylinder diameter)
Thickness
5-8 mm (cylinder wall thickness)
Density
Gram per cubic centimeter(g/cm3)
Thermal Conductivity
Non-applicable (not used for insulation)
Water Absorption
Non-applicable (uses gas-based or clean agent suppression)
Water Content
Not applicable (gas-based system)
Refill Availability
Yes, easy cylinder refilling and replacement
Temperature Range
0C to +54C (operational)
Coverage Area
Up to 200 m2 per system (expandable)
Compliance Standard
UL, FM, EN 12094, NFPA 2001
System Lifespan
10-15 years with proper maintenance
Cylinder Finish
Red Epoxy Powder Coated
Activation Method
Automatic and Manual Actuation
Audio Alarm Output
90 dB @ 1m (typical)
Suppression Agent Options
FM-200, NOVEC 1230, CO2
Detection Method
Smoke and Heat Detectors
Operating Pressure
24-42 bar (varies by agent)
Control Panel
Microprocessor-based with fault and alarm indicators
Discharge Time
Typically less than 10 seconds
Pipe Material
Corrosion-resistant Stainless Steel or Galvanized Iron
Maintenance Requirements
Annual inspection; Bi-annual refilling check
SERVER ROOM SUPRESSION SYSTEM About
The best fire suppression systems for server rooms are clean agent systems such as FM200, Novec 1230, or inert gas systems, because they extinguish fires quickly without damaging sensitive electronic equipment .
FM200 (HFC227ea) Fast discharge, effective on Class C electrical fires.
Novec 1230 Low global warming potential, residuefree, safe for electronics.
Inert Gas Systems (Inergen, Argonite) Reduce oxygen to suppress fire without harming
NFPA 75 Fire protection for IT equipment; recommends clean agents or preaction sprinklers.
NFPA 76 Telecom facility fire protection.
NFPA 2001 Clean agent system design and safety requirements.
IBC Often requires automatic sprinkler systems in commercial buildings.
EPA SNAP Restricts highGWP agents and promotes environmentally friendly alternatives
Protect equipment without causing collateral damage.
Integrate suppression with HVAC shutdown and power isolation.
Ensure sealed room integrity for gasbased systems.
Regular testing and maintenance per NFPA guidelines
Rapid, Residue-Free Protection for Critical Infrastructure
Our server room suppression systems are engineered to safeguard mission-critical environments without leaving residue or damaging equipment. Utilizing advanced agents like FM-200, NOVEC 1230, or CO2, the system activates automatically or manually, suppressing fires in under 10 seconds. With corrosion-resistant stainless steel or galvanized iron pipes and a microprocessor-based control panel, it provides robust and reliable protection up to 200 m2 per system. Easy refilling and maintenance ensure system longevity and readiness at all times.
Advanced Detection and Actuation Designed for Server Rooms
Equipped with smoke and heat detectors, the system ensures early fire identification and swift activation. Users benefit from both automatic and manual actuation options, giving unparalleled flexibility and control. The control panel features clear LED visual status and high-decibel audio alarms, increasing safety and clarity in an emergency. Annual inspections and straightforward refilling procedures keep the system in peak condition and fully compliant with leading fire safety standards.
FAQ's of SERVER ROOM SUPRESSION SYSTEM:
Q: How is the server room suppression system activated during a fire emergency?
A: The system can be activated automatically through smoke and heat detectors or manually using dedicated actuation switches. Upon detection, the suppression agent is released within seconds to quickly extinguish the fire and protect vital equipment.
Q: What suppression agents are available and what are their advantages?
A: The available agents are FM-200, NOVEC 1230, and CO2. These clean agents offer rapid fire suppression without leaving any residue, are non-conductive, and are specifically chosen for their suitability in environments with sensitive electronics.
Q: When does the suppression agent discharge and how long does it take?
A: Once the control panel receives a signal from the detectors or manual activation, the suppression agent discharges typically in less than 10 seconds, ensuring swift fire control and equipment protection.
Q: Where can this suppression system be installed and what coverage does it provide?
A: The system is ideal for server rooms and critical IT spaces, covering up to 200 m2 per system. Multiple systems can be connected to protect larger areas, offering flexible installation options for distributors, service providers, and end-users.
Q: What is the maintenance process for the suppression system?
A: Annual inspections and bi-annual refilling checks are recommended. Refilling and cylinder replacement are designed for ease, ensuring continued operation and compliance with relevant safety standards.
Q: How does the system ensure clear notification and situational awareness during an emergency?
A: The control panel delivers visual alerts through LEDs and audio alarms at around 90 dB at 1 meter, providing clear and timely notification to personnel for swift evacuation and response.
Q: What are the main benefits of choosing this server room suppression system?
A: Key benefits include rapid, residue-free suppression, non-damaging protection for sensitive electronics, robust corrosion-resistant construction, and compliance with international safety standards. Easy maintenance and refill procedures further support operational reliability and safety.
Tell us about your requirement
Price:
Quantity
Select Unit
50
100
200
250
500
1000+
Additional detail
Mobile number
Email
Name
Comapny Name
Phone Number
Email Id
City / State
Confirm Your Requirement
Verification Code
Did not receive yet?
Resend OTP
You’re Done!
We have received your requirements and will reply shortly with the best price.