INDIRECT HIGH PRESSURE SYSYEM(IHP) Specification

  • Shape
  • Cylindrical
  • Coverage Area
  • Customizable based on design, typically large enclosed areas
  • Fire Extinguisher Type
  • Gas-based (clean agent/CO2/inert gas depending on system)
  • Technology
  • Indirect high-pressure suppression with agent release via pipe network
  • Control Type
  • Automatic and manual activation
  • Installation Type
  • Fixed, wall or rack mounted
  • Features
  • Multiple cylinder arrays, quick discharge, remote actuation, robust steel construction, corrosion-resistant finish
  • Product Type
  • CO2 FLOODING SYSTEM
  • Connectivity Type
  • Wired control system; can be integrated into building management system
  • Mounting Type
  • Horizontal rack mounted or vertical stand
  • Coating Type
  • Epoxy or polyester powder coated
  • Working Temperature
  • -30C to +55C
  • Energy Efficiency Rating
  • Not applicable (fire suppression system)
  • Operating Pressure
  • 200-300 Bar
  • Voltage
  • 24V DC (for control/sensor units)
  • Fire Class
  • Class A, B, C (suitable for solid, liquid, and gas fires)
  • Application
  • INDIRECT HIGH PRESSURE SUPPRESSION SYSTEM(IHP)
  • Max Flow Rate
  • Varies by system capacity, up to 1000 kg/min or more
  • Capacity
  • Typically 40-140 liters per cylinder (system scalable as needed)
  • Diameter
  • Cylinders typically 150-250 mm (varies by model)
  • Pressure
  • 200-300 Bar (typical working pressure)
  • Agent Release Method
  • Indirect (discharge via piping and nozzles)
  • Discharge Time
  • Less than 60 seconds (for typical installations)
  • Maintenance
  • Low, periodic inspection recommended
  • Environmental Impact
  • Low (if using clean agent or inert gas options)
  • Safety Devices
  • Pressure relief valves, safety interlocks
  • Refilling Option
  • On-site cylinder refilling available
  • Material
  • Seamless high-strength steel
  • Alert Mechanism
  • Alarm integration available
  • Corrosion Resistance
  • High, due to powder coated cylinders
  • System Configuration
  • Modular, can be expanded or reduced as per need
 
 

INDIRECT HIGH PRESSURE SYSYEM(IHP) About

The Indirect High-Pressure (IHP) system is a fire suppression system that utilizes a detection tube as a fire detection and system activation device, not as a discharge tube. Once the tube senses the fire, it ruptures, causing a drop in pressure that activates the Indirect Valve, diverting flow from the detection tube to the larger outlet port. CO2 agent is then discharged from the cylinder through diffuser nozzles, flooding the area and effectively suppressing the fire quickly and thoroughly. This system is ideal for applications where space is limited and traditional systems cannot be installed, ensuring immediate suppression at the point of fire within CNC machines, lathes, milling machines, and robotic cells. It is also suitable for sensitive electronic devices that require non-conductive, residue-free suppression and prevents short-circuit fires in electrical enclosures. The IHP system is designed for localized, equipment-level fire suppression, making it a perfect fit for enclosed telecom racks, data center micro-cabins, UPS cabinets, and network distribution boxes.

Modular & Scalable Protection

Configure the IHP System to fit your protection requirements-scale up for expansive facilities or down for smaller environments. Its flexible modular nature ensures optimal coverage tailored to any building's unique layout, accommodating future changes or expansion with minimal disruption.


Fast and Effective Fire Suppression

With a rapid discharge time of less than 60 seconds, the IHP System swiftly combats fires using gas-based agents like clean agent, CO2, or inert gases. The indirect piping network efficiently channels suppressant to the affected area, minimizing fire damage and downtime.


Robust Engineering for Reliability

The system's seamless high-strength steel construction, epoxy or polyester powder coating, and corrosion-resistant design ensure longevity. Safety mechanisms like pressure relief valves, safety interlocks, and alert integrations maximize operational dependability and protection.

FAQ's of INDIRECT HIGH PRESSURE SYSYEM(IHP):


Q: How does the Indirect High Pressure System (IHP) release the fire-suppressing agent?

A: The IHP system utilizes an indirect release method, deploying suppressing agents via a network of piping and nozzles. Upon activation-manual or automatic-the agent is rapidly discharged through strategically placed nozzles, distributing suppressant efficiently throughout the protected area.

Q: What types of fires can the IHP system extinguish?

A: This system is suitable for Class A, B, and C fires, effectively handling solid, liquid, and gas fire risks. Its flexibility and customizable configuration make it ideal for varied applications, such as server rooms, industrial spaces, and storage facilities.

Q: When should the IHP system be inspected or maintained?

A: Though the system requires low maintenance, periodic inspection is recommended to ensure all components function optimally. Regular checks help detect any issues with the cylinders, valves, or alert systems and confirm that the refilling option is readily available on-site.

Q: Where can the IHP system be installed?

A: Designed for fixed placement, the IHP can be wall or rack mounted and is meant for enclosed areas of varying sizes. Its modular approach allows installation in locations where both scalability and comprehensive fire coverage are necessary.

Q: What is the process for refilling cylinders after discharge?

A: The system offers convenient on-site cylinder refilling, allowing for prompt restoration of fire protection capabilities without the need to remove cylinders from the premises-minimizing downtime and maintaining continuous safety.

Q: How does integrating alarms and building management systems benefit users?

A: With alarm integration and optional connectivity to building management systems, occupants receive real-time alerts and monitoring, enabling immediate response during emergencies and enhancing overall facility safety and situational awareness.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Co2 Flooding/Suppression System Category

Red Color Automatic Co2 Flooding System

Red Color Automatic Co2 Flooding System

Price 55000 INR / Piece

Minimum Order Quantity : 100 Pieces

Warranty : 1 YEARS

Temperature Range : CELSIUS Celsius (oC)

Usage : FIRE SUPPRESSION SYSTEM FOR ELECTRICAL PANEL

Weight : KG Kilograms (kg)

High Pressure Co2 Automatic Fire Extinguishing System

High Pressure Co2 Automatic Fire Extinguishing System

Price 55000 INR / Piece

Minimum Order Quantity : 100 Pieces

Warranty : 1 YEARS

Temperature Range : CELSIUS Celsius (oC)

Usage : FIRE SUPPRESSION SYSTEM

Weight : KG Kilograms (kg)

Co2 Fire Flooding System

Co2 Fire Flooding System

Price 100000 INR / Piece

Minimum Order Quantity : 1 Piece

Warranty : 1 YEARS

Temperature Range : CELSIUS Celsius (oC)

Usage : For Industrial Use

Weight : KG Kilograms (kg)

Gas Based Co2 Flooding System

Gas Based Co2 Flooding System

Price 51000 INR / Piece

Minimum Order Quantity : 100 Pieces

Warranty : 1 YEARS

Temperature Range : CELSIUS Celsius (oC)

Usage : FIRE SUPPRESSION SYSTEM

Weight : KG Kilograms (kg)



" We mainly want inquiries from Gujarat, Rajasthan, Madhya Pradesh, Maharashtra, Goa. "