Call UsCall Us 07971670816
INDIRECT HIGH PRESSURE SYSYEM(IHP)
INDIRECT HIGH PRESSURE SYSYEM(IHP)
INDIRECT HIGH PRESSURE SYSYEM(IHP)
INDIRECT HIGH PRESSURE SYSYEM(IHP)
INDIRECT HIGH PRESSURE SYSYEM(IHP)
INDIRECT HIGH PRESSURE SYSYEM(IHP)
INDIRECT HIGH PRESSURE SYSYEM(IHP)
INDIRECT HIGH PRESSURE SYSYEM(IHP)
INDIRECT HIGH PRESSURE SYSYEM(IHP)
INDIRECT HIGH PRESSURE SYSYEM(IHP)
INDIRECT HIGH PRESSURE SYSYEM(IHP)
INDIRECT HIGH PRESSURE SYSYEM(IHP)

INDIRECT HIGH PRESSURE SYSYEM(IHP)

Price 75000.0 INR/ Number

MOQ : 1 Number

INDIRECT HIGH PRESSURE SYSYEM(IHP) Specification

  • Product Type
  • CO2 FLOODING SYSTEM
  • Features
  • Multiple cylinder arrays, quick discharge, remote actuation, robust steel construction, corrosion-resistant finish
  • Fire Class
  • Class A, B, C (suitable for solid, liquid, and gas fires)
  • Energy Efficiency Rating
  • Not applicable (fire suppression system)
  • Technology
  • Indirect high-pressure suppression with agent release via pipe network
  • Coating Type
  • Epoxy or polyester powder coated
  • Operating Pressure
  • 200-300 Bar
  • Voltage
  • 24V DC (for control/sensor units)
  • Working Temperature
  • -30C to +55C
  • Fire Extinguisher Type
  • Gas-based (clean agent/CO2/inert gas depending on system)
  • Shape
  • Cylindrical
  • Control Type
  • Automatic and manual activation
  • Coverage Area
  • Customizable based on design, typically large enclosed areas
  • Installation Type
  • Fixed, wall or rack mounted
  • Connectivity Type
  • Wired control system; can be integrated into building management system
  • Mounting Type
  • Horizontal rack mounted or vertical stand
  • Application
  • INDIRECT HIGH PRESSURE SUPPRESSION SYSTEM(IHP)
  • Max Flow Rate
  • Varies by system capacity, up to 1000 kg/min or more
  • Capacity
  • Typically 40-140 liters per cylinder (system scalable as needed)
  • Diameter
  • Cylinders typically 150-250 mm (varies by model)
  • Pressure
  • 200-300 Bar (typical working pressure)
  • Alert Mechanism
  • Alarm integration available
  • Maintenance
  • Low, periodic inspection recommended
  • Material
  • Seamless high-strength steel
  • Safety Devices
  • Pressure relief valves, safety interlocks
  • Agent Release Method
  • Indirect (discharge via piping and nozzles)
  • Refilling Option
  • On-site cylinder refilling available
  • System Configuration
  • Modular, can be expanded or reduced as per need
  • Corrosion Resistance
  • High, due to powder coated cylinders
  • Discharge Time
  • Less than 60 seconds (for typical installations)
  • Environmental Impact
  • Low (if using clean agent or inert gas options)
 
 

INDIRECT HIGH PRESSURE SYSYEM(IHP) About

The Indirect High-Pressure (IHP) system is a fire suppression system that utilizes a detection tube as a fire detection and system activation device, not as a discharge tube. Once the tube senses the fire, it ruptures, causing a drop in pressure that activates the Indirect Valve, diverting flow from the detection tube to the larger outlet port. CO2 agent is then discharged from the cylinder through diffuser nozzles, flooding the area and effectively suppressing the fire quickly and thoroughly. This system is ideal for applications where space is limited and traditional systems cannot be installed, ensuring immediate suppression at the point of fire within CNC machines, lathes, milling machines, and robotic cells. It is also suitable for sensitive electronic devices that require non-conductive, residue-free suppression and prevents short-circuit fires in electrical enclosures. The IHP system is designed for localized, equipment-level fire suppression, making it a perfect fit for enclosed telecom racks, data center micro-cabins, UPS cabinets, and network distribution boxes.

Modular & Scalable Protection

Configure the IHP System to fit your protection requirements-scale up for expansive facilities or down for smaller environments. Its flexible modular nature ensures optimal coverage tailored to any building's unique layout, accommodating future changes or expansion with minimal disruption.


Fast and Effective Fire Suppression

With a rapid discharge time of less than 60 seconds, the IHP System swiftly combats fires using gas-based agents like clean agent, CO2, or inert gases. The indirect piping network efficiently channels suppressant to the affected area, minimizing fire damage and downtime.


Robust Engineering for Reliability

The system's seamless high-strength steel construction, epoxy or polyester powder coating, and corrosion-resistant design ensure longevity. Safety mechanisms like pressure relief valves, safety interlocks, and alert integrations maximize operational dependability and protection.

FAQ's of INDIRECT HIGH PRESSURE SYSYEM(IHP):


Q: How does the Indirect High Pressure System (IHP) release the fire-suppressing agent?

A: The IHP system utilizes an indirect release method, deploying suppressing agents via a network of piping and nozzles. Upon activation-manual or automatic-the agent is rapidly discharged through strategically placed nozzles, distributing suppressant efficiently throughout the protected area.

Q: What types of fires can the IHP system extinguish?

A: This system is suitable for Class A, B, and C fires, effectively handling solid, liquid, and gas fire risks. Its flexibility and customizable configuration make it ideal for varied applications, such as server rooms, industrial spaces, and storage facilities.

Q: When should the IHP system be inspected or maintained?

A: Though the system requires low maintenance, periodic inspection is recommended to ensure all components function optimally. Regular checks help detect any issues with the cylinders, valves, or alert systems and confirm that the refilling option is readily available on-site.

Q: Where can the IHP system be installed?

A: Designed for fixed placement, the IHP can be wall or rack mounted and is meant for enclosed areas of varying sizes. Its modular approach allows installation in locations where both scalability and comprehensive fire coverage are necessary.

Q: What is the process for refilling cylinders after discharge?

A: The system offers convenient on-site cylinder refilling, allowing for prompt restoration of fire protection capabilities without the need to remove cylinders from the premises-minimizing downtime and maintaining continuous safety.

Q: How does integrating alarms and building management systems benefit users?

A: With alarm integration and optional connectivity to building management systems, occupants receive real-time alerts and monitoring, enabling immediate response during emergencies and enhancing overall facility safety and situational awareness.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Co2 Flooding/Suppression System Category

Co2 Gas Fire Suppression System

Co2 Gas Fire Suppression System

Price 51000 INR / Bottle

Minimum Order Quantity : 20 Bottles

Application : Industrial Facilities, Power Plants, Data Centers, Marine, Electrical Rooms, Transformer Areas

Gas Based Co2 Flooding System

Gas Based Co2 Flooding System

Price 51000 INR / Piece

Minimum Order Quantity : 100 Pieces

Application : FIRE SUPPRESSION SYSTEM FOR ELECTRICAL PANEL

Product Type : FIRE SUPPRESSION SYSTEM

Warranty : 1 YEARS

Color : RED

ELECTRICAL PANEL CO2 GAS FLOODING SYSTEM

ELECTRICAL PANEL CO2 GAS FLOODING SYSTEM

Price 30000.0 INR / Number

Minimum Order Quantity : 1 Number

Application : ELECTRICAL PANEL CO2 GAS FLOODING SYSTEM

Product Type : CO2 FLOODING SYSTEM

Co2 Fire Flooding System

Co2 Fire Flooding System

Price 100000 INR / Piece

Minimum Order Quantity : 1 Piece

Application : FIRE SUPPRESSION SYSTEM FOR ELECTRICAL PANEL

Product Type : FIRE SUPPRESSION SYSTEM

Warranty : 1 YEARS

Color : RED



" We mainly want inquiries from Gujarat, Rajasthan, Madhya Pradesh, Maharashtra, Goa. "
Back to top