Fire Suppression System (Capacitor Panel) Specification
Installation Type
Direct/Panel Mounting
Coverage Area
Depends on panel size (customizable)
Energy Efficiency Rating
NA (Not rated)
Technology
Automatic Fire Suppression
Working Temperature
-30°C to 55°C
Shape
Cylindrical/Compact canister
Fire Extinguisher Type
Clean Agent Gas (ABC type extinguishing media)
Connectivity Type
Standalone/No external connectivity required
Mounting Type
Inside capacitor/electrical panel
Voltage
Not required (automatic, mechanical activation)
Operating Pressure
8-15 bar (depending on model)
Control Type
Automatic Trigger/Release
Features
Compact design, rapid response, no electrical dependency, minimal residue
Fire Class
Class A, B, C Fires
Coating Type
Corrosion-resistant powder coating
Application
Electrical Capacitor Panel Fire Protection
Capacity
500g to 5kg (varies by model and panel size)
Pressure
Medium Pressure System
Environmental Impact
Ozone safe, zero residue, non-conductive
Detection Mechanism
Heat-sensitive glass bulb or Linear Heat Sensing Tube
Maintenance
Low, annual inspection recommended
Material of Construction
Mild steel or Stainless Steel cylinders
Service Life
5 Years (typical, dependent on model)
Agent Type
Specialized clean agent gas (HFC-227ea or FK-5-1-12)
Compatibility
Compatible with electrical/electronic panel equipment
Refillable
Yes
Discharge Type
Total flooding/Local application
Noise Level
Silent operation
Weight
Varies (as per capacity, 1.2kg typical)
Discharge Time
Less than 10 seconds
Fire Suppression System (Capacitor Panel) Trade Information
Minimum Order Quantity
25 Sets
Payment Terms
Cheque
Main Export Market(s)
Asia
Main Domestic Market
All India
Fire Suppression System (Capacitor Panel) About
Fire Suppression (Capacitor Panel) Features:
Full-automation heating start, no electricity
High effectively
Simple Installation and maintenance
Suitable for electric equipment
Refillable
Reliable Protection for Sensitive Electrical Equipment
This fire suppression solution is designed specifically for capacitor and electrical panels, providing fast, automatic response to fire hazards. The advanced detection mechanism promptly identifies heat from incipient fires, triggering total flooding or local application discharge. Its non-conductive, clean agent gas minimises risk to electrical components, while the compact, robust construction ensures long-term reliability under various operating temperatures.
Environmentally Friendly and Maintenance-Efficient
Engineered with an eco-conscious clean agent (HFC-227ea or FK-5-1-12), our system ensures ozone safety and zero residue. The design eliminates electrical dependency and lowers overall maintenance-an annual inspection is typically sufficient. Its refillable feature supports sustainable use, while corrosion-resistant coatings extend the product's service life and safeguard sensitive environments.
FAQ's of Fire Suppression System (Capacitor Panel):
Q: How does the fire suppression system detect and respond to a fire within capacitor panels?
A: The system utilises either a heat-sensitive glass bulb or a Linear Heat Sensing Tube installed inside the panel. When it senses elevated temperatures, the detection mechanism triggers automatic activation, discharging the clean agent gas directly to the fire source in under ten seconds.
Q: What clean agent gases are used and are they safe for electronics and the environment?
A: Our fire suppression system employs specialized clean agents (HFC-227ea or FK-5-1-12) that are non-conductive, leave zero residue, and do not harm sensitive electrical or electronic equipment. Both agents are environmentally friendly, ozone-safe, and suitable for use in occupied areas.
Q: When and how should maintenance be performed on these systems?
A: The system requires minimal maintenance; typically, an annual inspection is recommended to check pressure, agent levels, and general functionality. Refilling is possible after discharge, ensuring continued usability and cost-efficiency throughout its 5-year typical service life.
Q: Where can this fire suppression system be installed?
A: This system is engineered for direct mounting inside capacitor panels or other electrical/electronic panels. Its compact design and customizable capacity allow for flexible installation tailored to the specific size and layout of the equipment enclosure.
Q: What is the process for refilling or recharging the system after a discharge?
A: After a discharge event or routine maintenance, the cylinders can be professionally refilled with the appropriate clean agent gas by an authorized service provider or supplier in India. Refilling helps maintain operational readiness while reducing long-term replacement costs.
Q: What are the key benefits of using this automatic fire suppression system?
A: Users gain rapid, automatic fire detection and suppression with minimal residue, ensuring uninterrupted operation of electrical panels. The system operates silently, does not require an external power source, and supports eco-friendly and maintenance-efficient panel protection.
Tell us about your requirement
Price:
Quantity
Select Unit
50
100
200
250
500
1000+
Additional detail
Mobile number
Email
Name
Comapny Name
Phone Number
Email Id
City / State
Confirm Your Requirement
Verification Code
Did not receive yet?
Resend OTP
You’re Done!
We have received your requirements and will reply shortly with the best price.
Products You May Like
More Products in Fire Suppression Systems Category