DIRECT LOW PRESSURE FIRE SUPPRESSION SYSTEM Specification

  • Voltage
  • 24V DC (control panel)
  • Product Type
  • CLEAN AGENT SYSTEM
  • Features
  • Automatic activation, integrated detection, modular system, easy refilling
  • Connectivity Type
  • Wired connectivity to alarm and monitoring systems
  • Energy Efficiency Rating
  • Not applicable (passive system)
  • Fire Class
  • Class A, B, and C
  • Fire Extinguisher Type
  • Clean agent automatic extinguisher
  • Working Temperature
  • 0C to 55C operational
  • Color
  • RED
  • Control Type
  • Automatic, electronic control panel
  • Shape
  • Cylindrical
  • Coating Type
  • Corrosion-resistant powder coating
  • Operating Pressure
  • 15-20 bar (varies by agent and cylinder)
  • Coverage Area
  • Typically up to 2 cubic meters per cylinder (varies with configuration)
  • Installation Type
  • Wall/Panel mounted
  • Mounting Type
  • Panel/cabinet mount
  • Technology
  • Direct Release Detection and Suppression
  • Application
  • ELECTRICAL PANEL
  • Max Flow Rate
  • Defined by discharge nozzle, typical for DLP cylinders
  • Diameter
  • Standard cylinder, approx. 6-8 inches
  • Capacity
  • Typically 2-10 kg (varies by model)
  • Pressure
  • Stored pressure system, generally 15-20 bar
  • Compliance Standard
  • NFPA 2001, IS 15519:2004, or equivalent specification
  • Maintenance Interval
  • Annual inspection recommended
  • Indication
  • LED status indicator on control unit
  • Cylinder Material
  • Seamless steel
  • Weight
  • Approx. 8-15 kg (depending on size and fill)
  • Agent Type
  • Clean agent such as FM200 or Novec 1230
  • Alarm Integration
  • Compatible with external alarm/notification system
  • Discharge Duration
  • Typically less than 10 seconds
  • Detection Method
  • Thermally sensitive tubing or sensor cable
  • System Reset
  • Manual reset after discharge
 
 

DIRECT LOW PRESSURE FIRE SUPPRESSION SYSTEM About



Experience supreme fire safety with the DLP SYSTEM-an optimum solution renowned as a best-seller in electrical panel protection. Engineered for value, this system guarantees best price performance, leveraging thermally sensitive tubing or sensor cable for uninterrupted fire detection. A seamless steel cylinder filled with FM200 or Novec 1230 clean agents provides immediate, automatic suppression upon fire detection. The gorgeous red, corrosion-resistant cylindrical unit offers modular installation, LED status indication, and effortless refilling. Built to NFPA 2001, IS 15519:2004, or equivalent standards, it provides annual reliability, quick manual reset, and easy integration with external alarms for comprehensive peace of mind.

Optimal DLP SYSTEM Application: Advanced Features for Essential Protection

The DLP SYSTEM is designed for automatic, direct release fire detection and suppression within electrical panels. Its standout features include integrated thermally sensitive tubing, swift activation under 10 seconds, a modular design for easy installation and expansion, and compatibility with external alarm systems. The system effectively covers up to 2 cubic meters per cylinder, making it ideal for compact yet crucial areas. Gorgeous corrosion-resistant construction and low-maintenance refilling ensure premium, lasting protection for critical infrastructure.


Domestic Market Reach and Sample Policy for DLP SYSTEM Orders

We ensure streamlined order processing and secure shipping across India, prioritizing safe freight for every unit. As an esteemed DLP SYSTEM manufacturer, distributor, supplier, and wholesaler, we serve all major domestic markets. Samples are available upon request under our fair sample policy, enabling clients to evaluate product quality firsthand before large-scale procurement. Our reliable freight partners guarantee the arrival of each system in optimum condition, reflecting our commitment to complete customer satisfaction.


FAQ's of DLP SYSTEM:


Q: How does the DLP SYSTEM detect and suppress fires within electrical panels?

A: The DLP SYSTEM utilizes thermally sensitive tubing or sensor cables to detect heat or fire. Upon detection, it automatically activates the clean agent suppressant (FM200 or Novec 1230), discharging it in less than 10 seconds for immediate extinguishing.

Q: What benefits does the DLP SYSTEM offer over conventional fire extinguishers?

A: This system provides optimum, immediate protection without the need for human intervention, is modular for easy expansion, integrates with alarm systems, and uses clean agents safe for sensitive electronics. Its quick activation and refillable design make it low maintenance and highly reliable.

Q: Where can the DLP SYSTEM be installed and what is its coverage area?

A: The DLP SYSTEM is specifically designed for electrical panels and similar enclosures. Each cylinder generally covers up to 2 cubic meters, making it perfect for compact yet critical locations where fire risk needs immediate suppression.

Q: What is the process for resetting and maintaining the DLP SYSTEM after discharge?

A: After discharge, the system requires a manual reset and refilling by authorized personnel. Annual inspection is recommended for compliance and reliability, as outlined by standards such as NFPA 2001 and IS 15519:2004.

Q: When can customers expect secure shipment and what sample policies are in place?

A: Order processing begins immediately after confirmation, with secure shipping and reliable freight partners ensuring prompt delivery. Samples are available under a clear, customer-friendly policy, allowing for evaluation prior to bulk ordering.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Suppression Systems Category

Fm200 Gas Based Fire Suppression Systems

Fm200 Gas Based Fire Suppression Systems

Price 100000 INR / Set

Minimum Order Quantity : 20 Sets

Application : Server rooms, Data centers, Telecommunications, Electrical cabinets, Control rooms, Industrial and commercial areas

Voltage : 24V DC for electrical release

Max Flow Rate : Varies as per system design (approx. 2832 kg/sec)

Nitrogen Injection Transformer Fire Protection System

Nitrogen Injection Transformer Fire Protection System

Price 750000 INR / Set

Minimum Order Quantity : 1 Set

Application : Transformer Fire Protection

Voltage : 230V AC

Max Flow Rate : 30 Nm3/hr

Electrical Panel Fire Suppression

Electrical Panel Fire Suppression

Price 25000 INR / Piece

Minimum Order Quantity : 1 Piece

Application : FIRE SUPPRESSION SYSTEM FOR ELECTRICAL PANEL

Product Type : FIRE SUPPRESSION SYSTEM

Hfc 227ea Based Fire Suppression System

Hfc 227ea Based Fire Suppression System

Price 85000 INR / Piece

Minimum Order Quantity : 1 Piece

Application : FIRE SUPPRESSION SYSTEM FOR ELECTRICAL PANEL

Product Type : FIRE SUPPRESSION SYSTEM



" We mainly want inquiries from Gujarat, Rajasthan, Madhya Pradesh, Maharashtra, Goa. "
Back to top