Price 50000.0 INR/ Piece

MOQ : 1 Piece

NOVAC 1230 FIRE SUPPRESSION SYSTEM Specification

  • Installation Type
  • Floor-mounted with wall-mount or vertical mount option
  • Voltage
  • Control panel operates at 230V AC / 24V DC
  • Product Type
  • SERVER ROOM SUPPRESSION SYSTEM
  • Fire Extinguisher Type
  • Fixed (total flooding) Gas Suppression System
  • Coverage Area
  • Varies based on system design, typically 50 to 300 sq.m. per cylinder
  • Connectivity Type
  • Panel-based electrical connectivity
  • Coating Type
  • Corrosion-resistant Powder Coated Cylinder
  • Control Type
  • Automatic and Manual Control
  • Fire Class
  • Class A, B, C
  • Energy Efficiency Rating
  • Non-applicable (non-power consuming device)
  • Working Temperature
  • 0C to +54C
  • Operating Pressure
  • 25 bar (360 psi) nominal
  • Features
  • Environmentally safe, electronics-friendly, zero ozone depletion potential, low GWP
  • Mounting Type
  • Floor mounted with bracket restraint
  • Technology
  • Clean Agent Fire Suppression System
  • Shape
  • Cylindrical
  • Application
  • SERVER ROOM
  • Max Flow Rate
  • Specified as per design and application (typically up to 1000 lpm depending on system layout)
  • Capacity
  • Varies (Available in 10L, 20L, 40L, and custom sizes)
  • Diameter
  • Standard cylinder diameters vary (consult manufacturer)
  • Pressure
  • Standard 25 bar (360 psi) charging pressure
  • Cylinder Material
  • High Strength Steel
  • Discharge Time
  • 10 Seconds or less
  • System Response Time
  • < 30 seconds depending on detection type
  • Refilling Life
  • Up to 10 Years (subject to periodic inspection)
  • Safety
  • Non-toxic, safe for personnel, non-corrosive
  • Pipe Material
  • Stainless Steel SCH40/SCH80 or as specified
  • Maintenance
  • Annual Inspection and as per NFPA 2001
  • Alarm Output
  • Audible & Visual Alarm with automatic system isolation
  • Agent Type
  • NOVEC 1230 (FK-5-1-12)
 
 

NOVAC 1230 FIRE SUPPRESSION SYSTEM About

The NOVEC 1230 fire suppression system is a clean agent system that rapidly extinguishes fires by absorbing heat, leaving no residue, and ensuring safety for people, property, and the environment.

How NOVEC 1230 Works

NOVEC 1230 uses 3M Novec 1230 fluid, a fluorinated ketone, as its fire-extinguishing agent. Stored as a liquid under pressure with nitrogen, it is released as a gas when the system detects a fire through heat or flame sensors. The agent works primarily by absorbing heat from the fire, interrupting the combustion process without significantly reducing oxygen levels, allowing occupants to safely exit the area during discharge 119firecontrol.com+2. Unlike water-based systems, it does not damage sensitive electronics, documents, or artwork



Comprehensive Fire Protection for Sensitive Electronic Areas

The NOVAC 1230 Fire Suppression System is purpose-built for facilities such as server rooms, where safeguarding electronic assets is critical. By using environmentally safe NOVEC 1230 agent, which is non-toxic and non-corrosive, the system ensures maximum protection without damaging sensitive equipment or threatening personnel safety.


Fast and Effective Fire Suppression

With a discharge time of 10 seconds or less and a system response time of under 30 seconds, the NOVAC 1230 system activates swiftly to stop fire at its early stage. This rapid response minimizes damage, supports business continuity, and provides peace of mind for operators of critical infrastructure.


Low Maintenance and Long Service Life

Periodic inspections and annual maintenance, as outlined by NFPA 2001 guidelines, help keep the NOVAC 1230 system at peak performance. Featuring up to 10 years of refilling life and corrosion-resistant powder-coated cylinders, this system is designed for reliability and longevity.

FAQ's of NOVAC 1230 FIRE SUPPRESSION SYSTEM:


Q: How does the NOVAC 1230 Fire Suppression System operate during a fire event?

A: The system detects fire through automatic sensors or manual activation, triggers both audible and visual alarms, and rapidly releases the NOVEC 1230 agent through stainless steel piping, extinguishing the fire within 10 seconds without residue or equipment damage.

Q: What types of fires can the NOVAC 1230 system effectively suppress?

A: The system is engineered to protect against Class A (ordinary combustibles), Class B (flammable liquids), and Class C (electrical) fires, making it especially suitable for electronic assets and data centers.

Q: When is maintenance required for the NOVAC 1230 system?

A: Routine maintenance should be performed annually as per NFPA 2001 standards, alongside periodic inspections to ensure reliable system operation and to maintain the agent's shelf life of up to 10 years.

Q: Where can the NOVAC 1230 system be installed?

A: It is ideal for critical areas such as server rooms, data centers, communication facilities, and other spaces containing high-value electronic assets. Installation configurations can be tailored to specific room sizes and layouts.

Q: What is the process for refilling or servicing the NOVAC 1230 system?

A: The system is designed for easy refilling, typically at intervals up to 10 years, subject to regular inspections. Only authorized and trained service providers should handle refilling and servicing to maintain safety and compliance.

Q: Can the NOVAC 1230 system be integrated with existing building alarm systems?

A: Yes, it uses panel-based electrical connectivity and can be configured to communicate with building management and alarm systems for coordinated response and enhanced safety.

Q: What are the benefits of choosing this system over traditional fire extinguishing solutions?

A: NOVAC 1230 offers rapid suppression without leaving residue, is non-corrosive and non-toxic, safe for personnel, and environmentally friendly with zero ozone depletion and low global warming potential, thus ensuring protection for both people and sensitive equipment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Suppression Systems Category

Novec 1230 Flooding System

Novec 1230 Flooding System

Price 75000 INR / Piece

Minimum Order Quantity : 1 Piece

Connectivity Type : Wired (integrated with Fire Alarm Control Panel)

Coating Type : Corrosion Resistant Powder Coated Cylinders

Control Type : Automatic & Manual Control

Fire Class : Class A, B, and C

Fire Detection And Fire Suppression System

Fire Detection And Fire Suppression System

Price 50000 SGD ($ / Set

Minimum Order Quantity : 5 Sets

Connectivity Type : Wired to fire detection panel, relay output

Coating Type : Corrosion resistant epoxy coating

Control Type : Automatic/manual

Fire Class : Class A, B, C (Solids, Flammable liquids, Electrical equipment)

Fm200 Gas Based Fire Suppression Systems

Fm200 Gas Based Fire Suppression Systems

Price 100000 INR / Set

Minimum Order Quantity : 20 Sets

Connectivity Type : Wired/Integrated with Fire Alarm System

Coating Type : Epoxy / Powder Coated

Control Type : Automatic and Manual

Fire Class : Class A, B, C

Heavy Vehicle Fire Suppression Systems

Heavy Vehicle Fire Suppression Systems

Price 82000 INR / Set

Minimum Order Quantity : 20 Sets

Connectivity Type : Wired, CAN Interface

Coating Type : Powder Coated Steel

Control Type : Manual and Automatic

Fire Class : Class A, B, E



" We mainly want inquiries from Gujarat, Rajasthan, Madhya Pradesh, Maharashtra, Goa. "
Back to top